This simple, yet elegant system is ideal for accurate, repeatable measurements of optical filters, glass and ophthalmic lenses.
Weve combined our expertise in miniature spectrometers and accessories with experience as a manufacturer of precision optics to create a compact system for real-time transmittance measurement of ophthalmic lenses and other optical components.
The Ocean Optics Optical Transmittance Spectrophotometer (OTiS光學(xué)透射系統(tǒng)) is ideal for both in-line and in-lab applications where transmittance accuracy (to +/- 1.0%) and precision (+/- 0.1%) are critical. Common applications include measurement of optical coatings, windows and filters, and glass and plastic components.
About the System The OTiS光學(xué)透射系統(tǒng) covers the 380-780 nm wavelength range and accepts samples from 10-150 mm in diameter and up to 10 mm thickness. The system comprises several components:
-
High-resolution miniature linear CCD-array spectrometer configured for 380-780 nm
-
High-power, 20-watt tungsten halogen light source
-
Fiber optic integrating sphere for collecting signal transmitted through the sample
-
光學(xué)透射系統(tǒng)Optics for improved beam collimation and spectral sensitivity distribution
-
Sample fixture (z-stage) to hold sample in place and exclude ambient light
-
Short optical fiber to channel signal from the integrating sphere to the spectrometer
-
Customized lens transmittance and color calculation software
| Under the Hood |
| Characteristics |
| Spectral range: |
380-780 nm |
| Detection: |
Miniature fiber optic spectrometer |
| Light source: |
High-power tungsten halogen (360-2000 nm) |
| Sample collection: |
Fiber optic integrating sphere |
| Color calculations: |
CIE L*a*b* color characteristics |
| Measurement calibration: |
Manual calibration using known filter standard (not included); calibration time <30 seconds |
| System calibration: |
Recommend annual recalibration |
| Transmittance calibration standards: |
Available (contact an Applications Scientist for details) |
| Typical samples measured: |
Windows, filters, glass and plastic lenses |
| Sample size: |
10-150 mm diameter, up to 10 mm thickness |
| Optical stage: |
White powder-coated aluminum (optional black anodized aluminum version available) |
| Software: |
Customized lens transmittance and color calculation software |
| Quality: |
Calibration referenced to accepted standards |
| Manufacturing compliance: |
CE/UL/RoHS/WEEE |
|
| Performance |
| Transmittance measurement accuracy: |
+/-1.0% |
| Transmittance measurement precision: |
+/-0.1% |
| Data acquisition time: |
<5.0 seconds |
| Light source output: |
20 watts |
| Light source stability: |
0.5% (~15 minutes to stabilize) |
| Light source drift: |
<0.3% per hour |
| Bulb lifetime: |
2,000 hours |
| Bulb color temperature: |
3,000 K |
| Operating temperature: |
5 C - 35 C |
| Operating humidity: |
5-95% at 40 C |
|
| Computer & Power Requirements |
| Operating systems: |
Windows Operating System |
| Computer interfaces: |
USB 2.0 @ 480 Mbps |
| Power requirements: |
100-240V, 50-60 Hz, 1.5A | |
|