Light Sources>> Wavelength Calibration Sources>>HG-1 Mercury Argon Calibration Source for UV-VIS  

HG-1 Mercury Argon Calibration Source


The compact, low-cost HG-1 Mercury Argon Calibration Source is a spectral wavelength calibration source for UV-VIS-Shortwave NIR spectrophotometric systems. The HG-1 produces first order mercury and argon spectral lines from 253-922 nm and second order argon lines to 1700 nm for use in performing fast, reliable spectrometer wavelength calibrations. Easily identifiable mercury and argon spectral emission lines are printed on the HG-1 housing.

The HG-1 is available for

With the HG-1 and an Ocean Optics spectrometer, users can perform wavelength calibration with a spreadsheet program such as Microsoft Excel or a calculator that performs linear regressions. For technical assistance in performing the latter option, click on Calibrating the Wavelength of Your Spectrometer.

The HG-1 features an SMA 905 Connector to couple to Ocean Optics spectrometers and fiber optic accessories, including optical fibers. The HG-1 operates with a 12 VDC power supply (included with the unit) or 9V battery (not included).

User's Tip: Ocean Optics spectrometers are carefully calibrated as part of the company's standard quality assurance process. However, as is the case with all spectrometers, wavelength will drift slightly due to time and environmental conditions. If wavelength accuracy is an important part of your work, consider including calibration spectra with every experiment.

Specifications

Output:

Low-pressure gas discharge lines of mercury and argon

Spectral range:

253-1700 nm

Dimensions (in mm):

125.7 x 70 x 25.8

Power consumption:

250 mA at 12 VDC

Power requirements:

12 VDC wall transformer (included) or
9 VDC battery (additional)

Internal voltage:

600 volts at 30 kHz

Bulb life:

~ 3,500 hours (at 20 mA)

Amplitude stabilization:

~1 minute

Aperture:

3 mm

Connector:

SMA 905

User's Tip: Ocean Optics recommends using the HG-1 with a 50 µm-diameter or smaller optical fiber or entrance slit. The use of  fibers and slits >50 µm in diameter will result in optical resolution (full width, half maximum) that adversely affects wavelength calibration. Also, keep in mind that if the spectrometer has no slit and your experiment involves using optical fibers of different diameters, wavelength re-calibration will be required. That's because optical resolution will vary according to the diameter of the fiber in use -- i.e., a 50 µm fiber will resolve differently than a 100 µm fiber, and so on. Recalibration is also recommended every time that you unscrew the fiber from the SMA 905 Connector on the spectrometer.

Spectral Output

Mercury emission lines are <600 nm. Argon emission lines are >600 nm, and are shown here on an exaggerated amplitude scale.

Strong Hg Emission Lines by Wavelength (nm)

User's Tip: There are more emission lines published here than printed on the label on the HG-1 housing. The label is intended as a quick, convenient reference and does not list every Ar or Hg emission line that exists.

253.652 404.656
296.728 407.783*
302.150 435.833
313.155 546.074**
334.148 576.960
365.015 579.066

* This spectral line will not be evident with spectrometers configured with 300- or 600-lines/mm gratings.

** With spectrometers that have 1200-, 1800-, 2400- or 3600-lines/mm gratings, spectral lines will be evident at 576.96 nm and 579.07 nm.

Strong Ar Emission Lines by Wavelength (nm)

696.543 800.616*
706.722 811.531
714.704 826.452
727.294 842.465
738.398 852.144
750.387 866.794
763.511 912.297
772.376 922.450
794.818

* This spectral line will be evident only with spectrometers configured with 1800-, 2400-, or 3600-lines/mm gratings.

Cuvette Wavelength Calibration Adapter

The PS-HG1-ADP Wavelength Calibration Adapter is a 1-cm square fixture that fits into a 1-cm pathlength sample chamber and connects to the HG-1 via optical fiber. (Neither wavelength calibration standard or fiber is included). The adapter is designed for performing a wavelength calibration for any spectrometer and 1-cm cuvette holder system, whether it's designed by Ocean Optics or another manufacturer.

 
版权所有 2007 广州标旗光电科技发展股份有限公司 www.ywhswzhs.com
地址:广州市黄埔区彩频路7号701-1房
电话:(020)38319602 38319620 传真:(020)38319595 ICP备案:粤ICP备2024341827号 粤公网安备44011202002999
主站蜘蛛池模板: 国内精品影院久久久久 | αv天堂| 国产午夜亚洲精品一区网站 | 日韩欧美一区二区三区 | 久久精品国产一区二区三区日韩 | 欧美日韩国产亚洲一区二区三区 | 精品久久久久久亚洲精品 | 99精品久久 | 欧美一区二区在线观看 | 奇米影视亚洲狠狠色777不卡 | 毛片免费网站 | 国产一区日韩二区欧美三区 | 看一级特黄a大片日本片黑人 | 国产一区亚洲欧美成人 | 国产一成人精品福利网站 | 欧美日韩综合高清一区二区 | 黄视频免费 | 欧美黄色一级毛片 | 奇米色在线| 成年人视频在线免费播放 | 国产精品久久久久久久久久直 | 国产激情毛片 | 日本欧美综合免费视频 | 国产精品永久免费视频 | 人成免费网站 | 激情毛片| 久草在线看 | wwwww在线观看| 激情视频免费在线观看 | 国产人人澡| 成人中文字幕在线观看 | www.亚洲天堂| 久久久精品一区 | 国产精品高清一区二区三区不卡 | 不卡视频一区 | 老司机精品在线观看 | 69欧美另类xxxxx高清 | 国产午夜视频在线观看 | 成人拍拍视频 | 日韩欧美一区二区三区在线播放 | 精品国产午夜久久久久九九 |