Product

OceanOpticsSpectrometer>> Plasma Spectroscopy>>Laser Assisted Microwave Plasma Spectroscopy  

LAMPS (Laser Assisted Microwave Plasma Spectroscopy), developed in conjunction with Envimetrics, represents a huge leap forward in LIBS technology.

LAMPS features a specially designed microwave cavity to enhance plasma discharge, thereby increasing sensitivity for most potential analytes. Also enhanced are emission line stability and reproducibility, leading to better quantification results. Applications for a variety of diverse analytes requiring greater sensitivity and less ablative sample imprint are now made possible with LAMPS.


LAMPS vs. LIBS Technology
Current LIBS technology permits qualitative analysis of a solid or liquid sample by ablating a minute portion of it, then analyzing the resulting plasma. LAMPS takes this a step further by employing a special microwave cavity. The plasma is injected into this cavity where it reacts with free electrons, greatly increasing sensitivity and producing better line stability and reproducibility. A lower power 50 mJ laser is used in the LAMPS, resulting in less ablation imprint to the sample and greater sensitivity.

LAMPS Components
Spectrometers -- The key to LIBS and LAMPS measurements is the ability to acquire high resolution spectra over a broad wavelength range of a transient event. This is accomplished by coupling 7 HR2000+ spectrometers into one system. Each spectrometer covers ~100-140 nm typically starting at 200nm for Channel A and ending with 980nm for Channel G.

Systems may be configured to start below 200 nm and with fewer channels for element-specific applications. Optical resolution is ~ 0.1nm FWHM. Pixel resolution is ~ 0.05 nm/pixel. In a 7-channel system, there are 14,336 pixels acquiring synchronous spectra. The detector integration time can be as low as 1 ms, and the maximum data transfer rate to the PC is about 500 spectra (14,336 values) per second over the USB 2.0 port.

Sample Chamber -- Provides critical eye safety by using laser safety shielding and safety interlocks on the door. The sample stage is a manual x, y and z positioner, with internal LED illumination for sample positioning. A fiber bundle, inserted inside the microwave cavity, is constructed with a special dielectric tip so that no metals are introduced into the cavity.

The next release will feature a redesign of the power supply so that it will be housed inside the sample chamber, weigh less, and will sustain plasmas greater than 2 ms. CE certification is pending the release of this next generation power supply.

Laser -- We provide Quantel's 50 mJ CFR Pulsed Nd:YAG Laser with our LAMPS system. The CFR design is especially rugged as both resonator mirrors are on the same rigid metal plate. The laser is mounted to the sample chamber and aligned to the focusing optics. A 100 mm lens with manual z-axis control permits focusing or allows defocusing of the laser for better plasma uniformity.

Software – OOILIBS operating software provides control of the lasers; has user-programmable delay for the Q switch; acquires, plots and saves spectra; and provides a spectral line library and correlation function for identification of peaks.

Spectra can be exported to Excel. Application-specific libraries of peaks can be loaded. You can zoom into a wavelength range to look for a peak in the library by double-clicking on the line in the table. Or, the correlation routine will match peaks to wavelengths in the library and rank the elements by how many of the emission lines it found. The user can set baseline and peak width filters for the search.

 

Under the Hood
Dimensions:  

LAMPS Sample Chamber

72.5 x 35.3 x 43.9 cm

Spectrometer System

33.4 x 15.0 x 14.0 cm maximum

Weight:

 

LAMPS Sample Chamber

22.7 kg

Spectrometer System

6.4 kg

Wavelength range

200-980 nm (channel dependent)

Optical Resolution

~ 0.1nm FWHM

Pixel resolution

~ 0.05 nm/pixel

Frame rate

2 per second (with microwave on)

Integration time

1-2 ms

Trigger delay

Programmable in software

Trigger jitter

20 ns

Trigger level

+5V TTL

Microwave frequency

2.45 GHz

Microwave power

1 KW @ 2.5 ms

 
版权所有 2007 广州标旗光电科技发展股份有限公司 www.ywhswzhs.com
地址:广州市黄埔区彩频路7号701-1房
电话:(020)38319602 38319620 传真:(020)38319595 ICP备案:粤ICP备2024341827号 粤公网安备44011202002999
主站蜘蛛池模板: 国产精品久久久精品三级 | www.国产精品视频 | 奇米色影 | 成人毛片18女人毛片免费 | 18成人免费观看视频 | 91视频入口 | 毛片日韩| 国产福利在线看 | 国产亚洲精品va在线 | 国产日韩久久久久69影院 | 国产精品亚洲欧美日韩区 | 欧美bbbbbxxxxx | 国产成人精品免费视频网页大全 | 91大片淫黄大片.在线天堂 | 精品国产成人在线 | 日本高清福利视频在线观看 | 国产va视频 | 成人毛片18女人毛片免费视频未 | 精品在线免费观看视频 | 欧美一区二区激情视频 | 成 年 人 黄 片 大全 | 日本黄在线观看免费播放 | 奇米影视奇米四色888av | 国产男女猛视频在线观看网站 | a久久99精品久久久久久不 | 国产精品久久亚洲一区二区 | 草草影院浮力 | 国产日韩欧美在线观看 | 国产一区二区久久久 | 国产va在线视频观看 | 成人爱爱免费视频 | www.精品久久 | a网站在线观看 | a一区二区三区视频 | 欧美在线看片a免费观看 | 国内精品综合九九久久精品 | 成年女人在线观看片免费视频 | 看看屋午夜| 国产传媒一区二区三区呀 | 国产一区亚洲欧美成人 | 青青视频在线播放 |